Adjust the donor so that about 0.8 in. (2 cm) protrudes

from the receiver magazine.

●

Cut the leading end square. Make sure that the width of

the protruding end does not vary by more than 0.12 in.

(3 mm).

●

Use care so that the receiver's leading end does not

slip back into the receiver magazine. If it does, it will be

impossible to pull out the receiver.

6

.

Close the left-hand side upper door. Grasp the receiver

leading end and slowly insert the receiver magazine along

the guide.

IMPORTANT:

If the magazine is inserted with the donor's leading end bent,

the machine may multifunction.

NOTE:

Push the receiver magazine all the way in.

7

.

Close the front upper door.

★

The machine will automatically cut off and discharge

the unusable portion of the receiver's leading end.

IMPORTANT:

●

Do not open the door during the receiver discharge

process. Receiver jamming may occur.

●

Do not turn the power switch to OFF ( ) or disconnect

the power plug during the receiver discharge process.

Receiver jamming may occur.