FujiFilm 4500N User Manual

Page 42

Advertising
background image

33

3

OPERA

TING PR

OCDURES

3

.

Remove the core of the receiver magazine and adjust the

partitions to the receiver being used. The size of the receiver

must correspond to the donor as shown below.

Size of receiver

Corresponding donor size

315 mm (Double Letter Wide,etc.)

323mm

279 mm (Double Letter and Letter)

305mm

254 mm (10 x 12 and 10 x 8)

262mm

127 mm (5R,etc.)

135mm

102 mm (4R,etc.)

135mm

NOTE:

Use the proper combination of donor and receiver. Do not use

combinations other than those above. If you do, the message

"Warning Check Magazine Type" appears.

4

.

Take out the receiver magazine from the casing and inner

bag. Take the roll of the new receiver and insert the plastic

flanges into the right-hand and left-hand sides of the roll.

5

.

Pull out the leading edge of the receiver about 0.8 in. (2

cm) and insert it into the receiver replacement magazine.

Then close the cover and lock both sides firmly.

6

.

Specify the type of receiver being used with the dip switch

on the receiver magazine.

1

2

3

OFF

ON

Type

1

2

3

4

Standard thickness, glossy, SG

Thin glossy, LG

Standard thickness, matte, SM

Thin matte, LM

3.5 Receiver Magazine Replacement

Partitions

315mm

297mm

254mm

127mm

102mm

0.8 in.
(2 cm)

Dip Switch

Advertising