When storing the donor (the donor magazine) or receiver (the receiver magazine), place it in a

horizontal position. If stored in an upright position, the donor/receiver roll may become loose

and impossible to pull out of the magazine.

IMPORTANT:

If a sealed donor magazine/receiver magazine is left in a room for a long period

or in a hot and damp place, good printing quality may not be obtained. The

magazine must be stored in a cool, dark place not exposed to direct sunlight. If

the magazine will be stored for longer than one month, storage at

10

°

C, 60%RH or less is recommended.

●

When unsealing the donor (or the donor magazine), make sure that it is not exposed to direct

sunlight.

●

After a magazine is unsealed, it must not be placed on the floor or in a dusty location as

deterioration in print quality may result.

●

If the inner door of the donor magazine compartment (see (13) in 2.1) is open, the donor leading

edge will be exposed to extraneous light.

●

After a magazine is unsealed, it should be immediately inserted into the machine. If a donor

magazine is left in a bright place for extended periods of time, the donor will be exposed to

extraneous light and become unusable.

●

Prepare a magazine for each size of donor and receiver used. The donor is photosensitive.

Once a donor roll is inserted in a magazine, it cannot be replaced with another donor roll. It is

also recommended that the receiver not be replaced after insertion into a magazine, otherwise

deterioration in print quality may result.

IMPORTANT:

●

To assure good print quality, it is recommended that the donor/receiver be

used within one month after unsealing.

●

If the machine is not to be used for a period of longer than one week, take the

donor and receiver magazines out of the machine and store them in a cool

dark place. Also empty the water bottle.