freeStor 4020 User’s Manual

94

will cause the entire RAID to fail.

Note: In a linear configuration, the Hotplug Indicator is RED for all the disks
because removing any one of them will remove data from the storage system.
However, this will not adversely affect any of the other disks.

In addition, while a disk is being rebuilt, all the other disks are RED, since removing any one of
them at this point will cause the RAID to fail.

If you remove a viable disk and cause only RAID degradation, you can re-install the same disk
and resume normal operation. (For information about adding a disk, refer to Adding hard disks.)

Note: If you remove two or more disks, you must re-install them in the reverse
order to help maintain data integrity. For example, if you remove disk A from slot
1 and then remove disk B from slot 2, you must re-install disk B first, then disk A.
You can put the disks back into different slots, but they must be re-installed in the
opposite order from which they were removed.

If you remove one or more viable disks and cause the entire RAID to fail, you can shut down the
storage system, re-install the same disks, and then restart the storage system. As long as you
re-install the original disks, the storage system should be able to resume proper operation,
although the integrity of the data cannot be guaranteed. However, if you replace the removed
disks with new disks, you must reconfigure your disks.

Warning: Reconfiguring your disks will delete all the data on your storage
system.

Responding to RAID degradation

When disk removal/failure causes RAID degradation, the Disk Change Notification page
appears when you access the Manager or refresh the browser window (Figure A-3).

Figure A-3: Disk Change Notification Page – Degradation