Gas model testing & lighting instructions, Figure 7 – Garland MP-GD-10-S User Manual

Page 15

Advertising
background image

Part # MPSM07 (03/24/08)

Page 15

Turn on the main gas valve .
Remove the lower front trim cover . Drop the control panel

and leak test all fittings and connections upstream from the

service valve located on the redundant combination gas

valve . Should any gas leaks be detected turn OFF the main

gas valve, correct the problem and begin the test again .
Remove the blanking plug from the manifold test spigot and

connect a pressure test gauge .
Open the manual gas valve located behind the redundant

combination gas valve .
Activate the control panel and set the oven to the desired

temperature . The burner will now ignite .
During installation there will be air in the gas line . This air will

have to bleed off before ignition can occur . Wait five minutes

after each attempt to bleed the air from the lines .
Turn on all appliances supplied by the same gas line and

verify that the manifold pressure is 4 .5” WC for natural gas or

10” WC for propane gas .

GAS MODEL TESTING & LIGHTING INSTRUCTIONS

After the correct pressure has been verified, turn off the oven

and remove the pressure gauge from the manifold pressure

test spigot . Re-install the blanking plug .
Check all fittings again . Correct any leaks and begin the test

again .
Replace all control panels, service panels and covers before

operation .
All electronic ignition systems are supplied with a redundant

gas valve . Therefore, the oven is not supplied with an external

pressure regulator .

To Conserve Energy:

Do not waste energy by leaving the controls at high

temperature settings during idle periods . Lower settings will

keep the oven warm and ready for the next use period .

Figure 7.

A

TO ACCESS THE MANUAL SHUTOFF,

REMOVE THE THUMBSCREW FROM

THE CONTROL PANEL, UNPLUG

THE CONTROL FROM THE WIRING HARNESS,

AND REMOVE THE CONTROL PANEL TO

EXPOSE THE MANUAL SHUTOFF VALVE.

*** VIEW SHOWN

WITHOUT THE

BODY SIDE

FOR CLARITY***

3/4” MANUAL

GAS VALVE

A

REMOVE PLUG BUTTON TO

ACCESS PRESSURE ADJUSTMENT

FOR THE MANIFOLD

SAFETY SHUTOFF

SWITCH

FOR GAS VALVE

DETAIL A