Testing & troubleshooting – Garland MP-GD-10-S User Manual

Page 50

Advertising
background image

Part # MPSM07 (03/24/08)

Page 50

TESTING & TROUBLESHOOTING

Inputs

There are two input tabs to

accept 24VAC from the relay

board transformer (TR1) .

There are two sense lines . This circuit is internal, and

signals the control to turn on the “HEAT” message in

the lower right corner of the display . One circuit is

for gas ovens, the second is for electric ovens . Both

will use the same common terminal .

There are two 2 wire connections, one

for each door switch connection

There are two tabs each for the sense of the

1000 ohm RTD probes . One cavity probe

that must always be present, and one for an

optional core probe for use with cooking .

Advertising
This manual is related to the following products: