Diagnostic procedures – Garland MP-GD-10-S User Manual

Page 44

Advertising
background image

Part # MPSM07 (03/24/08)

Page 44

Fan Speed Test

1 . After selecting Fan Speed Test and pressing “ENTER”

(lower right blank), the control will turn the oven fan on

LOW speed for ten seconds . Verify that the fan is indeed

running on low speed . The control will show

2 . After a short while, the control will turn the fan on HIGH

speed for ten seconds . Verify that the fan is indeed on

high .

3 . After a few seconds, the test will complete . Press “CANCEL”

to return to Diagnostics Mode . .

Heat Test

1 . After selecting Heat Test and pressing “ENTER” (lower right

blank), the control will show the actual temperature of the

oven, and will turn the heaters on . Verify that the actual

temperature increases during the test .

2 . After a short while, the test will complete . Press “CANCEL”

to return to Diagnostics Mode .

Moisture Test

1 After selecting Moisture Test and pressing “ENTER”, the

control will show the moisture status as OFF for ten

seconds .

2 . The control will then turn moisture on for ten seconds,

verify that the moisture has actually turned on within the

oven by looking through the glass door .

3 . After a few seconds, the Moisture Test will complete . Press

“CANCEL” to return to Diagnostics Mode .

Temperature Calibration

1 . After selecting Temperature Calibration and pressing

“ENTER”, the display will show the Actual Temperature

inside the oven . Verify the cavity temperature using a

pyrometer .

NOTE: If the oven temperature is below 200°F, Temperature

Calibration will not be active and the display will show Low

Temp.

2 . Press and hold the “TEMP” (upper right blank) key for

three, (3), seconds . The display will show the Actual

Temperature on the first line and Set Temperature on the

second line .

If the Actual Temperature does not correspond to the

pyrometer, enter the value on the pyrometer using

buttons 1 – 0 . The value will be input as Set Temp .

3 . Press “ENTER” (lower right blank) to accept the changes .

The Actual Temperature will change to equal the

value input for Set Temperature . Press Cancel to exit

Temperature Calibration .

• After the desired Tests are complete, press “CANCEL” to exit

Diagnostics Mode .

Control Safety Features

The control has several built in safety features to protect both

the user and the oven itself .

DIAGNOSTIC PROCEDURES

Advertising
This manual is related to the following products: