TESTING & TROUBLESHOOTING

MP-GS-10/20 Troubleshooting Guide
Use this chart with the appropriate wiring diagram, also found in this manual

Mechanical Control

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

Fan will not Run

No Power to Oven

Turn power on

No Power to Oven

Check Light circuit – IF OK, Select “Cook” and Check

Timer circuit . IF OK, Check Door Micro Switches

Micro switch not OPENING

Check connections & switch functions .

(Caution: the switch components on this control

system pass 115 v . a .c . through switch contacts .)

Fast Control

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

Key Pad Buttons Not

Responding

Defective key pad

Use key pad diagnostics / pin outs test points

Loose ribbon connection at key pad

Check connection

PROBE ERROR in display

Faulty Probe

Replace probe

Loose probe connection

Check connections

HI TEMP In display

Oven at too high a temp for product

Allow oven to cool

HELP In display

Faulty Probe

Replace probe

Motor centrifugal switch stuck

Check centrifugal switch

Gas valve (s), or Ignition System

Check heat generation system – ( Refer to Service

procedures (Heat generation system) - .page

Unit will not shut off

Unit above 150°F

Put unit into cool down, open door slightly

No HIGH speed But LOW

speed works

Bad key pad

Use diagnostic KEY PAD TEST

Bad K2 relay on board

Check for voltage out of K2 relay

Bad motor

Check motor

No LOW speed But HIGH

speed works

Bad key pad

Use diagnostic KEY PAD TEST

Bad K2 relay on board

Check for voltage out of K3

Bad motor

Check motor

Display is BLANK NO

POWER

Bad transformer

Check for 24VAC out of TR1 transformer

Bad harness connection

Check connections

Unit will not heat

No power out of K4 relay

Check for power out of K4 relay

No power out of Ignition Module MV

Complete a flame current check to osolate

Gas valve shutoff switch open, PV, MV,

or both valves stuck closed

Check for MV power at gas shutoff switch, and that

PV and MV opens on call for heat

Motor centrifugal not closing

Check motor centrifugal switch

Motor stops, then after a

period of time comes back

on

Thermal Trip on motor

Inspect rear clearance
Motor air intake is clear of lint/debris
Replace motor