Service procedures (removal/replacement) – Garland MP-GD-10-S User Manual

Page 59

Advertising
background image

Part # MPSM07 (03/24/08)

Page 59

Fig . 2

BA plate secured

to outer mount

hole increases

pressure on

cavity seal

RH Door Frame To Cavity Seal Adjustment

The RH door frame to cavity seal pressure can be increased or

decreased, by adjustment of the handle latch engagement

hook tension before the door handle locks closed .
Loosen the small set screw, position the handle hook target in

or out, and test for eff ect . Once the proper secure the target

set screw .

RH door

frame to

cavity seal

adjustment

area .

4 To gain access, remove the screws holding the panel in

place .

5 . Pull the panel towards the back of the oven to remove .
6 . Cavity probe is located ABOVE and to the RIGHT of the

cavity motor .

7 . Disconnect the 2 BROWN probe wires at the temperature

probe .

8 . The probe can now be removed from inside the oven .
9 . Reinstall the replacement probe in reverse manner .

Door To Cavity Seal Adjustments

1 . Close the door, and determine the area (s) of air leakage .

(Use of a dollar bill between the door, and cavity seal, is a

suffi cient reference .

2 Open the door and move upper, and lower, BA plate hold

down counter sunk screws .

3 . Position the door rod upper, and lower, BA plates to

increase, or decrease, pressure on the cavity seal, where

needed . (Refer to fi gures 1, and 2, )

BA plate

secured to

inner mount

hole reduces

pressure on

cavity sea

l .

Fig . 1

SERVICE PROCEDURES (REMOVAL/REPLACEMENT)