Component identification – Garland MP-GD-10-S User Manual

Page 41

Advertising
background image

Part # MPSM07 (03/24/08)

Page 41

COMPONENT IDENTIFICATION

Cavity Temperature Controls
Service Overview

Spritzer (Water Inlet) –

Purpose: This temperature switch assures water injection

will not be available below a cavity temperature that

would allow excessive puddle buildup on the cavity floor .

The switch will close at a temperature of 225°F on rise .

This low, but slightly above superheat value of water

temperature will enable a preference of low temperature

cooking .

Control Compartment Ambient Temperature –

Purpose: This control will automatically run the cooling fan

in the control compartment if the temperature reaches,

or exceeds 150°F . This function will assure maximum

air extraction of hot ambient control compartment air

during continuous operation, and intake of cooler outside

ambient air .

Spritzer

Temperature

Control

Cooling

Fan

Control

NOTE: Water can only be injected

after the oven has preheated to at

least 225°F (107°C) .