Testing & troubleshooting – Garland MP-GD-10-S User Manual

Page 54

Advertising
background image

Part # MPSM07 (03/24/08)

Page 54

TESTING & TROUBLESHOOTING

Direct Spark Ignition Detail
MPO Direct Spark Ignition Specifications and Module Box Connections

Manufacturer

JOHNSON CONTROLS INC .

Vendor Part #

G760BAD-1

Ignition Type

Direct Spark

High Voltage Cable Wire

Stranded

Ignition Source

High Voltage Spark

Maximum Cable Length

48” (1,220mm)

Flame Detection Means

Flame Rectification

Flame Detection Types

Remote Sensing

Minimum Flame Current

0 .3 Microampere

Flame Failure

Response Time

0 .8 Seconds Maximum

Spark Gap

0 .1” (2 .5mm)

Ignition Retrials

3

Safety Times

4 Seconds

Waiting Times

0 Seconds

Interpurge

30 Seconds

Loss Of Flame Signal Retrials

4 (Five Total Ignition Attempts)

Operation Current

24 VAC, 50/60 HZ, Nominal, 0 .2A

Nominal + Main Valve

Contact Rating (MV)

2A Continuous, 5A Inrush

Ambient Operating And

Storage Fluttered

-40 to 158 °F (-40 to 70°C)

Humidity

95% RH non-condensing

Wire Connections

Spark Options

RAJAH Connector

GROUND

5

LED

THS 2

M.V. 3

SENSE 4

Advertising