When the water system is energized, and the cavity is at a

temperature of 225°F (107°C) or higher, condensation mist

should appear from the water nozzle located above the fan,

and behind the air baffle plate (not shown) .

Nozzle

The Timer is a solid state timer on the control compartment

sidewall.

Deluxe (Fast Panel Moisture Control)

Moisture is controlled by pre-programmed choices selected

during the product cook cycle sequence . (See product cook

programming in the Operation Manual section) . Additional

moisture can be manually selected using the moisture key

pad .

COMPONENT IDENTIFICATION

Moisture Control
Mechanical Moisture Control

• The Moisture system applies water through the solenoid

in 1 second cycles .

• The scale settings are in seconds .
• Set to the low position, the water will cycle once every 60

seconds .

• Set to the 60 second position, the water will cycle 6 times

in 1 minute .

60

55

50

45

40

35

30

25

20

15

LOW

The control increases the cycle time frequencies by rotating in

a clockwise

Water pressure check:

Minimum water feed pressure: Fully open the pressure

regulator control knob to determine what the line pressure is .

The gauge should read at least 30 psi .
Regulator pressure: The regulator should be set at 20 psi

when the spritzer valve is energized .
One way to determine if water is being injected is to monitor

the pressure gauge . The static pressure reading will drop 6

- 10 psi when the solenoid valve is opening, or cycling .