8-10 TranSphere TS Wireless Extended Range IP Networking Transceivers – January 2008 GFK-2489

8

Data Interface Connectors

Three types of data interface connectors are used on TS Wireless transceivers. The first, the
LAN/ETH port (LAN on the AP, ETH on the remote), is a metallized RJ-45 connector. The
other two are standard modular types—RJ-12 for the COM1 port, and RJ-45 for the COM2
port. This section provides illustrations and pinout information for all of these connectors.

Caution

RADIO INTERFERENCE POTENTIAL

The transceiver meets U.S.A. FCC

Part 15, Class A limits when used with shielded data cables not exceeding 3 ft./0.9m.

LAN/ETH Port

This port is used to connect to an Ethernet network at an AP or to the endpoint of a Remote.

To connect a PC directly to the AP LAN port, an RJ-45 to RJ-crossover cable is required.
At the Remote, a straight-through cable is required.

To connect the AP to a Ethernet hub or bridge, use a straight-through cable.

The connector uses standard Ethernet RJ-45 cables and wiring. The pinout graphic and table
below may be used to construct a custom cable, if required.

LAN/ETH Port (RJ-45) Pinout

(viewed from the outside of the radio)

Pin Functions

Reference

1

Transmit Data (TX) Out

High

2

Transmit Data (TX) Out

Low

3

Receive Data (RX) In

High

4 Unused

--

5 Unused

--

6

Receive Data (RX) In

Low

7 Unused

--

8 Unused

--