GFK-2489

Chapter 2 Tabletop Setup and Evaluation 2-9

2

Step 4—Configure the Remote Radio

The instructions below summarize essential Remote settings for tabletop testing. For detailed
log-in and menu navigation instructions, see chapter 4, Remote Radio Management.

Log-in and Configuration

Prepare the Remote for configuration as follows:

1.

Connect a PC to the COM1 port on the radio.

2.

Establish a terminal session (using HyperTerminal, for example) using the following data
parameters:

19200 bps

8 bits • no parity

one stop bit (8N1)

hardware flow control disabled

VT100 emulation

NOTE: The exact parameters given above must be used for console terminal
communication. Improper settings are a common cause of difficulty.

3.

Press ENTER several times to receive the entranet> prompt. (The COM1/ETH LED blinks
to indicate data communication.)

4.

At the entranet> prompt, enter login. Press ENTER .

5.

At the next prompt, enter the username (the default username is admin). Press ENTER .

6.

At next prompt, enter the password (the default password is admin). Press ENTER . The
radio is now ready to accept commands.