Redundancy menu – GE GFK-2489 User Manual

Page 90

Advertising
background image


GFK-2489

Chapter 3 AP Management 3-57

3

Redundancy Menu

Redundancy is available only at the AP. The Redundancy Menu is used in protected
installations where a backup transceiver can be immediately placed online if a primary radio
fails. This protects against “single point of failure” scenarios. The Redundancy Menu contains
selections and settings that are used to manage redundancy functions.

Redundancy functions require the presence of a specially-constructed supervisory board
(MDS Part No.03-6061Axx). Ask your MDS representative for details.

Redundancy Menu

Please select the type of Redundancy Switchover Events to Configure

A) Redundacy Configuration

enabled

B) Network Event Triggers

C) Hardware Event Triggers

D) Redundancy Configuration Options

E) Force Switchover

Select a letter to configure an item, <ESC> for the prev menu

Redundancy Configuration

—This selection is used to enable or disable redundancy

operation. When the supervisory board detects an alarm condition, the currently selected
transceiver is disabled, and the backup transceiver comes online. [Enabled, Disabled;
Enabled]

Network Event Triggers

—This selection presents a submenu (see below) with Ethernet-

(network) related alarm conditions.

Network Event Triggers Menu

Description

Status

A) Network Interface Error

enabled


Please select the event that you want to trigger a Redundancy Switchover on.

Press <SPACE> to cycle through options, <ENTER> to accept, <ESC> to cancel

Hardware Event Triggers

—This selection presents a submenu (see below) with

parameters related to local alarm conditions.