Detailed command descriptions – GE GFK-2489 User Manual

Page 99

Advertising
background image


GFK-2489

Chapter 4 Remote Radio Management

4-5

4

Detailed Command Descriptions

ALARM

Displays the current alarm conditions by severity level. For each level, the
specific events that caused an alarm are listed, along with a brief description of
each alarm. Alarm levels are:

ALL—All alarm classes
INFORM—Non-persistent information
MINOR—Minor alarm
MAJOR—Major alarm
CRITICAL—Critical alarm

Optional argument:

HEX=

—Displays the hex bit codes for the current alarm condition by class. For

each specific event that causes an alarm, the corresponding bit is set. Event
numbers are matched to the appropriate hex code by a relationship of 2

n

.

APLIST

Configures a list of approved APs.

Optional arguments:

APx=<integer>

Configures a list of approved APs. X is a number from 1–50,

and integer is the serial number of an approved AP (1–99999999). To delete
an entry, enter a serial number of 0; this indicates that the slot is not filled.

AP1=<integer>Serial Number of approved AP

AP2=<integer>Serial Number of approved AP .

-to-

AP50=<integer>Serial Number of approved AP

CLEAR

—Clears all entries in the AP list. Be sure to set RESTRICT to OFF

before using this command to avoid restricting Remotes to associating with an
empty list.

CMD

—Displays all settable optional arguments and their current values. You

can copy this list to a text file as a record of your configuration.

RESTRICT=<ON|OFF>

—Turns on or off restricting registration to APs in the

list.

ON—The Remote can only associate with an AP on the list.
OFF—The Remote can associate with any AP.







Advertising