Cmos clear jumper – Gateway ALR 9200 User Manual

Page 86

Advertising
background image

74 Maintaining and Troubleshooting the Gateway ALR 9200 Server

CMOS Clear Jumper

The jumper at pins 1, 2, and 3 controls whether settings stored in CMOS
nonvolatile memory (NVRAM) are retained during a system reset.

1.

See “Changing a Jumper Setting” on page 73.

2.

Move the CMOS jumper from pins 1 and 2 to pins 2 and 3 (the Clear
CMOS memory position).

3.

Reinstall the access cover for your safety (using the original screws),
and connect the power cords to the system.

4.

Turn the system on. Wait for POST to complete and for the messages

NVRAM cleared by jumper

Press <F2> to enter Setup

to appear. This automatically reprograms CMOS to its default settings,
except for the password.

5.

Enter Setup and make any changes necessary (for example, changing
the boot device).

6.

Press

F

10

to save the new Setup configuration and exit Setup.

7.

Turn off the system, and disconnect all AC power cords from the
system.

8.

Again remove the access cover.

9.

Move the jumper from pins 2 and 3 back to pins 1 and 2 (the Protect
CMOS memory position).

10.

Reinstall the access cover using the original screws, and connect the
power cords to the system.

11.

Run BIOS Setup or the SSU to verify the correct settings. See
Chapter 5,

BIOS Setup

and Chapter 6,

The Server Setup Utility

for more

information on setting BIOS and SSU fields.

To Restore the Manufacturing Default CMOS Settings