108 Appendix D: Technical information Matrox Meteor-II /Digital

By default, all jumpers are in place. If more than one load (for
example, two line-locked cameras) are to be connected to the
TRIG, VSYNC, HSYNC, or CLKIN, the corresponding jumpers
should be removed.

Specifications

Electrical

Operating voltage and current:

5 V ±5%, 1.4 A

12 V ±10%, 30 mA

Power consumption:

7.36 watts

Environmental

Min./max. ambient operating temperature: 0°C - 55° C.

Min./max. storage temperature: -40° C - 75° C.

Max. altitude for operation: 3000 meters.

Max. altitude for transport: 12000 meters.

Operating humidity: 20 - 80% relative humidity
(non-condensing)