Multi-Tech Systems ISIHP-2U User Manual

Page 120

Advertising
background image

120

MultiModemISI Hybrid Series, ISIHP-2S/2U/4S/4U/4SD

Terminal Adapter AT Commands & S-Registers

#Xn Send Single/Multiple Xoff Characters

Values: n = 0 or 1

Default: #X0

Allows the TA to send either a single or multiple Xoff characters to exert

flow control to the terminal. The #X0 command (factory default setting)

causes one Xoff to be sent until the TA‘s buffer reaches the Xon level. The

#X1 command causes an Xoff to be sent for every character received after

the TA reaches its buffer full level.

#X0

One Xoff character sent until the buffer

reaches the Xon level (default)

#X1

Multiple Xoff characters sent for every

character received after buffer reaches the

full level.

&Fn Load Quick Setup Profile

Values: n = 0-4

Default: &F0

For quick setup, the TA includes Quick Setup Profiles. Each contains

configuration parameters for a specific type of port operation. To load a

Quick Setup Profile into active memory use the command &Fn, where n is

the number of the profile you want to load. You then can customize the

profile and store it with the &W command, so it loads automatically on

power-up or reset. These profiles are stored in permanent memory and are

not user-configurable.

&F0

Profile 0 — Modem-like async operation

(default)

&F1

Profile 1 — V.110 async operation

&F2

Profile 2 — V.120 async operation

&F3

Profile 3 — X.75 async operation

&F4

Profile 4 — PPP async operation

&Rn CTS Control

Values: n = 0, 1, or 2

Default: &R1 (CTS forced high)

Advertising