Multi-Tech Systems ISIHP-2U User Manual

Page 121

Advertising
background image

MultiModemISI Hybrid Series, ISIHP-2S/2U/4S/4U/4SD

121

Terminal Adapter AT Commands & S-Registers

Allows you to control the state of the CTS (Clear to Send) signal. Normally

the CTS signal follows the state of the RTS signal when TA is online.

&R0

CTS acts normally; that is, it follows RTS.

&R1

CTS is forced high, but still provides online

flow control.

&R2

CTS is forced high, but it drops on

disconnect for the period of time set by S10.

CTS still provides flow control when the TA

is online.

&Sn DSR Control

Values: n = 0, 1, or 2

Default: &S1 (DSR normal)

Controls the state of the DSR (Data Set Ready) signal on the RS232E/V.24

interface. A high DSR signal indicates to the computer that the TA is ready

to transmit data.

&S0

DSR is always high.

&S1

DSR acts normally; that is, it follows the

state of the CD signal, which goes high

when the ISIHP-2S/2U detects a carrier

signal, and goes low when the carrier signal

is lost.

&S2

DSR is always high, except on disconnect,

when it drops for the period of time set by

S10 and then goes high again.

&Vn View Port Configuration Parameters

Values: n = 0, 1, 2

Default: n/a

Allows you to view the port configuration parameters for ports 0 and 1.

This listing is the equivalent of both L5 and L6 combined.

&V0

Displays port 0 configuration parameters.

&V1

Displays port 1 configuration parameters.

&V2

Displays both port 0 and port 1

configuration parameters.

Advertising