Modem AT Commands & S-Registers

Range: 0-1

Default: 1 (enabled)

Used for testing and debugging only. Enables and disables V.32bis start-up

auto mode operation. Set S43 to zero (0) to disable start-up auto mode, or 1

(the default) to enable start-up auto mode.

S89

Off-line Time
Unit: 1 second

Range: 0, 5-255

Default: 0

Sets the length of time, in seconds, a modem waits in the off-line command

mode before it goes into standby mode. If S89 is set to 20 seconds, the

modem waits 20 seconds in off-line command mode before going into

standby mode. Setting S89 to zero (0) prevents the modem from ever

entering standby mode.
Setting S89 to any value between zero and five (1-4) effectively sets the

value to five, because five seconds is the minimum possible wait time.

S108

Line Code Control
Unit: Decimal

Range: 0, 1

Default: 1

Controls the line coding used by the modem.

S108 = 0

mu-law

S108 = 1

A-law (default)

S109

PCM Mode Control
Unit: Decimal

Range: 0–2

Default: 1

Controls the PCM ( pulse code modulation) mode (V.90 or K56Flex).

Determines which mode the modem will answer in for PCM connections.

S109 = 0

K56Flex support only

S109 = 1

Both V.90 and K56Flex supported

S109 = 2

V.90 support only

Advertising