Terminal Adapter AT Commands & S-Registers

speech call originated on that line. However, 3.1 kHz audio information

transfer capability is allowed on data lines (modem or fax) by most

switches. S55 also lets you define whether a progress indicator information

element (which indicates that the origination address of the POTS call is

non-ISDN) is sent with the SETUP message for the POTS port call. This

may help POTS port calls get through certain CO switches.

S1

Speech, no progress indicator

S2

3.1 kHz Audio, no progress indicator

S17

Speech, origination address is non-ISDN

S18

3.1 kHz Audio, origination address is non-ISDN

S56 Calling Party Number IE Settings

(applies to NET3 [!C0=2] switch type only)

Unit:

decimal ASCII code

Range: 128

Disable

Type of Number

0

Unknown,

16

International

32

National

48

Network specific

64

Subscriber

96

Abbreviated

Numbering Plan

0

Unknown

1

ISDN/telephony

3

Data

4

Telex

8

National standard

9

Private

Default: 128 (disabled)

Modifies the value of Octet 3 of the Calling Party Number Information

Element that is sent within the SETUP message for data and POTS port

(voice/modem/fax) calls. To set a specific number type and numbering

plan, select an option from the Type of Number section above and add its

value to the value of an option in the Numbering Plan section above. For

example, a National/ISDN Calling Party Number IE would be S56=33,

where 32 (National) + 1 (ISDN/telephony) = 33 (National/ISDN). If there

is no Data Directory Number (for data calls) nor Voice Directory Number

(for voice/modem/fax calls), no Calling Party Number IE is sent. By