MultiModemISI Hybrid Series, ISIHP-2S/2U/4S/4U/4SD

129

Terminal Adapter AT Commands & S-Registers

S10 DCD Drop Time

Unit: 50 ms

Range: 0–254, 255

Default: 20

Sets the amount of time the DCD signal will be dropped when a call is

disconnected if the DCD signal is configured for a momentary drop on

disconnect (&C2)

S25 DTR Drop Time

Unit: 100 ms

Range: 0, 1–255

Default: 5

Sets the time that DTR must remain low before the TA disconnects. The

S25 unit value for 0 is 40 ms. For values from 1 through 255, the unit value

is 100 ms.

S30 On-line Inactivity Timer

Unit:

1 minute

Range: n=0 Does not disconnect

n=1–255

Default: 0 (does not disconnect)

Makes the TA disconnect a data connection if no data is transmitted or

received for the specified time. It will NOT cause a POTS call (voice/

modem/fax) to disconnect. The timer restarts any time a data character

passes through the serial port (either sent or received). Disable the

inactivity timer by setting S30=0, which is the factory default setting. S30

currently works for + all protocols EXCEPT V.110.

S32 Escape Sequence Timeout

Unit: 100 ms

Range: 0–255

Default: 20

Sets the time allowed in an escape sequence from the receipt of the A in AT

to the receipt of the carriage return. If the S32 time interval expires before

you press E

NTER

, the escape sequence ends. The default time is 2 seconds.