Manitowoc Ice MARINE MODEL S1800 User Manual

Page 41

Advertising
background image

Section 6

Electrical System

Part Number 80-1634-3

6-3

2. REFRIGERATION SYSTEM
START-UP

The compressor starts after the 45-
second water purge, and it remains
on throughout the Freeze and
Harvest cycles.

The water fill valve is energized at
the same time as the compressor.

The harvest valve(s) remains on for
the first 5 seconds of the initial
compressor start-up and then shuts
off.

At the same time the compressor
starts, the condenser fan motor (air-
cooled models) is supplied with
power throughout the entire freeze
and harvest sequences.

The fan motor is wired through a fan
cycle pressure control, and may
cycle on and off. (The compressor
and the condenser fan motor are
wired through the contactor. Any time
the contactor coil is energized, the
compressor and fan motor are
supplied with power.)

Self-Contained — Refrigeration System Start-Up

Table 6-2. Self-Contained Models

2. Refrigeration System Start Up (5 Seconds)

Toggle Switch

ICE

Bin Switch

Closed

Control Board Relays
#1

Water Pump

OFF

#2

Harvest Valve (Left)

ON

#3

Harvest Valve (Right)

ON (When Used)

#4

Air Compressor

ON (When Used)

#5

Water Inlet Valve

ON

#6

Water Dump Valve

OFF

#7

Contactor Coil

Closed / ON

#7A

Compressor

ON

#7B

Condenser Fan Motor

OFF

Safety Controls (Which could stop ice machine operation)

High Pressure Cut-Out

Closed

Main Fuse (On Control Board)

Closed

SV3137-4

(89)

(55)

(88)

High

Pressure

Cutout

Control Board

L1

Ground

(2)

(6)

(5)

(1)
(7)
(4)

L2 or N

Water Valve

Harvest Valve

(20)

(21)

(22)

(61)

Dump Valve

Water Pump

(60)

(76)

(81)

(75)

(77)

(80)

(57)

(98)

(58)

(59)

(42)

Ice Thickness

Probe

Water Level Probe

Trans.

Fuse (7a)

L2

Terminates at

Pin Connection

(99)

Contactor Coil

(56)

Air Compressor

(26)

(25)

Low DC

Voltage

Plug

Bin Switch

Clean

OFF

ICE

(2)

(1)

(6)

(8)

(9)

(74)

Compressor

Run Capacitor

(Red)

(Yellow)

Fan Motor

PTCR

(45)

(46)

(50)

(51)

(85)

Overload

(Black)

(86)

Fan Cycle

Control

L1

Contactor

Contacts

Run Capacitor

Advertising