Manitowoc Ice MARINE MODEL S1800 User Manual

Page 57

Advertising
background image

Section 6

Electrical System

Part Number 80-1634-3

6-19

ICE/OFF/CLEAN TOGGLE SWITCH

Function

The switch is used to place the ice machine in ICE, OFF
or CLEAN mode of operation.

Specifications

Single-pole, single-throw switch. The switch is
connected into a varying low D.C. voltage circuit.

Check Procedure

NOTE: Because of a wide variation in D.C. voltage, it is
not recommended that a volt meter be used to check
toggle switch operation.

1. Inspect the toggle switch for correct wiring.

2. Isolate the toggle switch by disconnecting the Molex

connector.

3. Check continuity across the toggle switch terminals.

Note where the wire numbers are connected to the
switch terminals, or refer to the wiring diagram to
take proper readings.

4. Replace the toggle switch if ohm readings do not

match all three switch settings.

Switch Setting

Terminals

Ohm Reading

ICE

1-6

Open

1-2

Closed

2-6

Open

CLEAN

1-6

Closed

1-2

Open

2-6

Open

OFF

1-6

Open

1-2

Open

2-6

Open

Advertising