Manitowoc Ice MARINE MODEL S1800 User Manual

Page 77

Advertising
background image

Section 7

Refrigeration System

Part Number 80-1634-3

7-11

Safety Limit #2

Refer to page 7-11 for safety limit operation.

Harvest time exceeds 3.5 minutes for 500 consecutive harvest cycles.

SAFETY LIMIT NOTES

Because there are many possible external problems,
do not limit your diagnosis to only the items listed in
this chart.

A continuous run of 100 harvests automatically
erases the safety limit code.

The control board will store and indicate only one
safety limit – the last one exceeded.

If the toggle switch is moved to the OFF position and
then back to the ICE position prior to reaching the
100-harvest point, the last safety limit exceeded will
be indicated.

If a Safety Limit light did not flash prior to the ice
machine restarting, then the ice machine did not stop
because it exceeded a safety limit.

Possible Cause

Check/Correct

Improper installation

See “Installation/Visual Inspection Checklist”

Water system

Water area (evaporator) dirty
Dirty/defective water dump valve
Vent tube not installed on water outlet drain
Water freezing behind evaporator
Plastic extrusions and gaskets not securely mounted to the
evaporator
Low water pressure [20 psi (138 kPa) min.]
Loss of water from sump area
Clogged water distribution tube
Dirty/defective water fill valve
Defective water pump

Electrical system

Ice thickness probe out of adjustment
Ice thickness probe dirty
Bin switch defective
Premature harvest

Refrigeration system

Non-Manitowoc components
Water regulating valve dirty/defective
Improper refrigerant charge
Defective harvest valve
TXV flooding (check bulb mounting)

Advertising