Section 6

Electrical System

Part Number 80-1634-3

6-27

Diagnosing An Ice Machine That Will Not Run

!

Warning

High (line) voltage is applied to the control board
(terminals #55 and #56) at all times. Removing
control board fuse or moving the toggle switch to
OFF will not remove the power supplied to the
control board.

Step

Check

Notes

1

Verify primary voltage supply to ice
machine.

Verify that the fuse or circuit breaker is closed.

2

Verify the high-pressure cutout is closed.

The H.P.C.O. is closed if primary power voltage is present at terminals
#55 and #56 on the control board.

3

Verify control board fuse is OK.

If the bin switch light functions, the fuse is OK.

4

Verify the bin switch functions properly.

A defective bin switch can falsely indicate a full bin of ice.

5

Verify ICE/OFF/CLEAN toggle switch
functions properly.

A defective toggle switch may keep the ice machine in the OFF mode.

6

Verify low DC voltage is properly
grounded.

Loose DC wire connections may intermittently stop the ice machine.

7

Replace the control board.

Be sure Steps 1-6 were followed thoroughly. Intermittent problems are
not usually related to the control board.