Electrical System

Section 6

6-4

Part Number 80-1634-3

Freeze Sequence

3. PRE-CHILL

To pre-chill the evaporator, the
compressor runs for 30 seconds (60
seconds initial cycle) prior to water
flow.

The water fill valve remains on until
the water level probe is satisfied.

Self-Contained — Pre-Chill

Table 6-3. Self-Contained Models

3. Pre-Chill (60 Seconds Initial Cycle - 30 Seconds thereafter)

Toggle Switch

ICE

Bin Switch

Closed

Control Board Relays
#1

Water Pump

OFF

#2

Harvest Valve (Left)

OFF

#3

Harvest Valve (Right)

OFF (When Used)

#4

Air Compressor

OFF (When Used)

#5

Water Inlet Valve

On

#6

Water Dump Valve

OFF

#7

Contactor Coil

Closed / ON

#7A

Compressor

ON

#7B

Condenser Fan Motor

May Cycle ON / OFF

Safety Controls (Which could stop ice machine operation)

High Pressure Cut-Out

Closed

Main Fuse (On Control Board)

Closed

SV3137-3

(89)

(55)

(88)

High

Pressure

Cutout

Control Board

L1

Ground

(2)

(6)

(5)

(1)
(7)
(4)

L2 or N

Water Valve

Harvest Valve

(20)

(21)

(22)

(61)

Dump Valve

Water Pump

(60)

(76)

(81)

(75)

(77)

(80)

(57)

(98)

(58)

(59)

(42)

Ice Thickness

Probe

Water Level Probe

Trans.

Fuse (7a)

L2

Terminates at

Pin Connection

(99)

Contactor Coil

(56)

Air Compressor

(26)

(25)

Low DC

Voltage

Plug

Bin Switch

Clean

OFF

ICE

(2)

(1)

(6)

(8)

(9)

(74)

Compressor

Run Capacitor

(Red)

(Yellow)

Fan Motor

PTCR

(45)

(46)

(50)

(51)

(85)

Overload

(Black)

(86)

Fan Cycle

Control

L1

Contactor

Contacts

Run Capacitor

Advertising