Figure 7-2. Self-Contained Harvest Cycle

Harvest Cycle Refrigeration Sequence

Hot gas flows through the energized harvest valve,
heating the evaporator. The harvest valve is sized to
allow the proper amount of refrigerant into the
evaporator. This specific sizing (along with the proper
system refrigerant charge) assures proper heat transfer,
without the refrigerant condensing and slugging the
compressor.

HEAT
EXCHANGER

EVAPORATOR

CONDENSER

COMPRESSOR

EXPANSION VALVE

HOT GAS SOLENOID VALVE

AIR OR WATER

DRIER

STRAINER

RECEIVER

(WATER COOLED ONLY)

LOW PRESSURE VAPOR

LOW PRESSURE LIQUID

HIGH PRESSURE LIQUID

HIGH PRESSURE VAPOR

SV1570