Section 7

Refrigeration System

Part Number 80-1634-3

7-1

Section 7

Refrigeration System

Sequence of Operation

SELF-CONTAINED WATER -COOLED MODELS

Figure 7-1. Self-Contained Prechill and Freeze Cycle

Prechill Refrigeration Sequence

No water flows over the evaporator during the prechill.
The refrigerant absorbs heat (picked up during the
harvest cycle) from the evaporator. The suction pressure
decreases during the prechill.

Freeze Cycle Refrigeration Sequence

The refrigerant absorbs heat from water running over the
evaporator surface. The suction pressure gradually
drops as ice forms.

HEAT
EXCHANGER

EVAPORATOR

CONDENSER

COMPRESSOR

EXPANSION VALVE

HOT GAS SOLENOID VALVE

AIR OR WATER

DRIER

STRAINER

RECEIVER

(WATER COOLED ONLY)

LOW PRESSURE VAPOR

LOW PRESSURE LIQUID

HIGH PRESSURE LIQUID

HIGH PRESSURE VAPOR

X

SV1569