INSTALLATION/VISUAL INSPECTION CHECKLIST

WATER SYSTEM CHECKLIST

A water-related problem often causes the same
symptoms as a refrigeration system component
malfunction.

Water system problems must be identified and
eliminated prior to replacing refrigeration components.

Possible Problem

Corrective Action

Ice machine is not level

Level the ice machine

Condenser is dirty

Clean the condenser

Water filtration is plugged (if
used)

Install a new water filter

Water drains are not run
separately and/or are not
vented

Run and vent drains
according to the Installation
Manual

Line set is improperly
installed

Reinstall according to the
Installation Manual

Possible Problem

Corrective Action

Water area (evaporator) is
dirty

Clean as needed

Water inlet pressure not
between 20 and 80 psi
(1-5 Bar, 138- 552 kPa)

Install a water regulator valve
or increase the water
pressure

Incoming water temperature
is not between 35°F (1.6°C)
and 90°F (32.2°C).

If too hot, check the hot water
line check valves in other
store equipment

Water filtration is plugged (if
used)

Install a new water filter

Water dump valve leaking
during the freeze cycle

Clean/replace dump valve as
needed

Vent tube is not installed on
water outlet drain

See Installation Instructions

Hoses, fittings, etc., are
leaking water

Repair/replace as needed

Water fill valve is stuck open

Clean/replace as needed

Water is spraying out of the
sump trough area

Stop the water spray

Uneven water flow across the
evaporator

Clean the ice machine

Water is freezing behind the
evaporator

Correct the water flow

Plastic extrusions and
gaskets are not secured to
the evaporator

Remount/replace as needed