Refrigeration System

Section 7

7-14

Part Number 80-1634-3

Freeze Cycle Suction Pressure High Checklist

Freeze Cycle Suction Pressure Low Checklist

NOTE: Do not limit your diagnosis to only the items listed in the checklists.

Possible Cause

Check/Correct

Improper installation

See “Installation/Visual Inspection Checklist”

Discharge pressure

Discharge pressure is too high, and is affecting low side
(See “Freeze Cycle Discharge Pressure High Checklist” )

Improper refrigerant charge

Overcharged
Wrong type of refrigerant

Other

Non-Manitowoc components in system
Harvest valve stuck open
TXV flooding (check bulb mounting)
Defective compressor

Possible Cause

Check/Correct

Improper installation

See “Installation/Visual Inspection Checklist”

Discharge pressure

Discharge pressure is too low, and is affecting low side
(See “Freeze Cycle Discharge Pressure Low Checklist”)

Improper refrigerant charge

Undercharged
Wrong type of refrigerant

Other

Non-Manitowoc components in system
Improper water supply over evaporator (See “Water System Checklist” )
Loss of heat transfer from tubing on back side of evaporator
Restricted/plugged liquid line drier
Restricted/plugged tubing in suction side of refrigeration system
TXV starving