Section 6

Electrical System

Part Number 80-1634-3

6-25

DIAGNOSING WATER LEVEL CONTROL CIRCUITRY

Problem: Water Trough Overfilling During The

Freeze Cycle

Step 1 Start a new freeze sequence by moving the ICE/
OFF/CLEAN toggle switch to OFF, then back to ICE. (if
water flows with the switch off, check the water inlet
valve).

Step 2 Wait until the freeze cycle starts
(the freeze cycle starts when the water pump energizes).

Step 3 Disconnect water level probe wire from control
board and connect a jumper from the control board
terminal and any cabinet ground, then refer to chart.

Step 3

Important

This restart must be done prior to performing
diagnostic procedures. This assures the ice
machine is not in a freeze cycle water inlet valve
safety shut off mode. You must complete the entire
diagnostic procedure within 6 minutes of starting.

Important

For the test to work properly you must wait until the
freeze cycle starts, prior to connecting the jumper
wire. If you restart the test you must disconnect the
jumper wire, restart the ice machine, (step 1) and
then reinstall the jumper wire after the compressor
starts.

SV3135

GREEN WATER LEVEL LIGHT

WATER LEVEL PROBE CONNECTION

Step 3 Jumper wire connected from control board terminal to ground

Is water flowing into

the water trough?

The Water Level

Light is:

The Water Inlet Valve

Solenoid Coil is:

Cause

NO

ON

De-Energized

The water level probe is causing the problem.

Clean or replace the water level probe.

YES

ON

Energized

The control board is causing the problem.

YES

OFF

De-Energized

The water fill valve is causing the problem.