Section 6

Electrical System

Part Number 80-1634-3

6-7

6. HARVEST

The harvest valve(s) remains open
and the refrigerant gas warms the
evaporator. This causes the cubes to
slide, as a sheet, off the evaporator
and into the storage bin.

The sliding sheet of cubes swings the
water curtain out, opening the bin
switch. This momentary opening and
closing of the bin switch terminates
the Harvest Cycle and returns the ice
machine to the Freeze Cycle (steps
3-4).

The air compressor (when used)
remains energized throughout the
entire harvest cycle. The air
compressor will automatically
energize after 60 seconds when the
harvest cycle time exceeded 75
seconds in the previous cycle.

Table 6-6. Self-Contained Models

6. Harvest (Until Bin Switch Activation)

Toggle Switch

ICE

Bin Switch

Closed

Control Board Relays
#1

Water Pump

OFF

#2

Harvest Valve (Left)

ON

#3

Harvest Valve (Right)

ON (When Used)

#4

Air Compressor

ON (When Used)

#5

Water Inlet Valve

OFF

#6

Water Dump Valve

OFF

#7

Contactor Coil

Closed / ON

#7A

Compressor

ON

#7B

Condenser Fan Motor

OFF; May Cycle ON

Safety Controls (Which could stop ice machine operation)

High Pressure Cut-Out

Closed

Main Fuse (On Control Board)

Closed

SV3137-7

(89)

(55)

(88)

High

Pressure

Cutout

Control Board

L1

Ground

(2)

(6)

(5)

(1)
(7)
(4)

L2 or N

Water Valve

Harvest Valve

(20)

(21)

(22)

(61)

Dump Valve

Water Pump

(60)

(76)

(81)

(75)

(77)

(80)

(57)

(98)

(58)

(59)

(42)

Ice Thickness

Probe

Water Level Probe

Trans.

Fuse (7a)

L2

Terminates at

Pin Connection

(99)

Contactor Coil

(56)

Air Compressor

(26)

(25)

Low DC

Voltage

Plug

Bin Switch

Clean

OFF

ICE

(2)

(1)

(6)

(8)

(9)

(74)

Compressor

Run Capacitor

(Red)

(Yellow)

Fan Motor

PTCR

(45)

(46)

(50)

(51)

(85)

Overload

(Black)

(86)

Fan Cycle

Control

L1

Contactor

Contacts

Run Capacitor