5. symbols and definitions, Section 4 − installation, 1. specifications – Miller Electric ProHeat 35 User Manual

Page 16

Advertising
background image

OM-222 166 Page 10

3-5. Symbols And Definitions

.

Some symbols are found only on CE products.

A

Amperes

V

Volts

Alternating Current

X

Duty Cycle

IP

Degree Of

Protection

Hz

Hertz

Circuit Protection

Output

Increase

Line Connection

I

1

Primary Current

I

2

Rated Current

U

1

Primary Voltage

U

2

Load Voltage

Read Instructions

Three Phase Static

Frequency Con-

verter-Transform-

er-Frequency Con-

verter

I

1max

Rated Maximum

Supply Current

P

1max

Maximum Power

Consumption

Three Phase

Percent

Remote

Panel/Local

High Temperature

Voltage Input

Off

On

SECTION 4 − INSTALLATION

4-1. Specifications

Output

Frequency

Rated Output

Required

Reflective

Inductance

Amperes Input at

Rated Load Output

50 or 60 Hz,

Three-Phase

Overall

Dimensions

Weight

Frequency

Single

Output

Dual

Output

Inductance

400 V

460 V

575 V

kVA

kW

Dimensions

5 To 30

kHz

35 kW At

100% Duty

Cycle

350 A

(RMS), 700

V (RMS)

35 kW At

100% Duty

Cycle

700 A

(RMS),

700 V

(RMS)

2.5 To 50

μh

60 A

50 A

40 A

39

37

Length: 36-3/4 in

(993 mm)

Width: 21-1/2 in

(546 mm)

Height: 29 in

(737 mm)

227 lb

(103 kg)

Storage Temperature Range −40_ F (−40_ C) to 122_ F (50_ C)
*While idling

Advertising