Miller Electric ProHeat 35 User Manual

Page 51

Advertising
background image

OM-222 166 Page 45

S

OPEN − no cable or plug in place

ClntFR − This is the coolant flow rate (in GPM) from the cooler on a liquid-cooled system.

ClrSts − This is the status of the cooler. Possible labels:

S

Off

S

Flowing

The second diagnostic screen is available by again pressing and holding the Run Status

button and pressing the Parameters

Hz

V

A

kW

button.

VLnA−B: 460V Therm1: 75 DIAG2
VLnB−C: 460V Therm2: 75 Therm5: OPEN
VLnC−A: 460V Therm3: 75 ClrTmp: 77
VBus: 650V Therm4: OPEN RmtFlw: Off

System Diagnostic Screen

VLnA-B − This is the phase to phase line voltage between phases A and B.

VLnB-C − This is the phase to phase line voltage between phases B and C.

VLnC-A − This is the phase to phase line voltage between phases C and A.

VBus − This is the DC bus voltage.

Therm1 − This is the temperature of the current source primary heatsink.

Therm2 − This is the temperature of the bridge heatsink.

Therm3 − This the the temperature of the current source secondary heatsink.

Therm4 − Open (not used).

Therm5 − Open (not used).

ClrTmp − This is the temperature of the coolant on a liquid-cooled system.

S

OPEN − no cooler is detected.

RmtFlw − This is the status of the relay contacts for remote coolant flow on a liquid-cooled system.

S

OFF

S

ON

.

RmtFlw feature is unsupported on the current platform.