OM-222 166 Page 46

9-7. Removing Wrapper and Measuring Input Capacitor Voltage

!

900 Volts dc can be present

on the capacitor bus and

significant DC voltage can

remain on capacitors after

unit is Off. Always check the

voltage on inverter assembly

as shown to be sure the input

capacitors have discharged

before working on unit.

!

Turn Off welding power

source, and disconnect

input power.

!

Significant DC voltage can

remain on capacitors after

unit is Off. Always check the

voltage as shown to be sure

the input capacitors have

discharged before working

on unit.

Remove right side panel and dis-

connect fan motor FM3.
1

Current Source Interconnect

Board PC4

2

Voltmeter

Measure the dc voltage across the

+ bus terminal and − bus terminal on

PC4 as shown until voltage drops to

near 0 (zero) volts.

.

If the capacitor voltage does
not drop to near zero after

several minutes, use a bleeder

resistor of between 200 and

500 ohms, at least 10 watts,

and #16 AWG 600 volts ac in-

sulation rated wire to discharge

the capacitor(s).

3

Typical Bleeder Resistor

An example of a typical bleeder

resistor is shown on this page.
Proceed with job inside unit. Re-

connect FM3 and reinstall right side

panel when finished.

Tools Needed:

5/16, 3/8 in

804 519-B

1

2

+ lead to right bus terminal,

− lead to left bus terminal

3

Typical Bleeder Resistor

#16 AWG 600 Volts AC

Insulation Rating

200 to 500 ohm, 10 watt

wire wound resistor