9. system operating characteristics – Miller Electric ProHeat 35 User Manual

Page 43

Advertising
background image

OM-222 166 Page 37

6-9. System Operating Characteristics

The power source delivers a high-frequency alternating current output that energizes the coil creating the magnetic field used to heat the workpiece.

The power source output characteristics are a function of the configuration, type and number of coils used as shown in the following table:

Table 6-1. Power Source Output Characteristics

Output Type

Maximum Amperage

Maximum Voltage

Frequency Range

Air Cooled Single and Dual

250 A per output for 15 minutes.

After 15 minutes, power steps

down to limit current to 150 am-

peres per output for continuous

operation.

700 V

5 − 25.7 kHz

See Note 1

700 V

25.7 − 30 kHz

Single Liquid Cooled

350 A

700 V

5 − 20 kHz

Single Liquid Cooled

See Note 2

700 V

20 − 30 kHz

Dual Liquid Cooled

350 A per output/700 A total

700 V

5 − 20 kHz

Dual Liquid Cooled

See Note 2

700 V

20 − 30 kHz

.

Note 1: In the frequency range
of 25.7 to 30 KHz, the maxi-

mum output amperage de-

creases linearly from 250 down

to 175 amperes per output. Re-

gardless of frequency, after 15

minutes the maximum output is

reduced to 150 amperes per

output.

M

ax

Amperage Per Output

Frequency (KHz)

5

25.7

30

0

50

100

150

200

250

300

Air Cooled Output

.

Note 2: In the frequency range
of 20 to 30 KHz, the maximum

output decreases linearly from

350 down to 175 amperes per

output.

M

ax

Amperage Per Output

Frequency (KHz)

5

20

30

0

50

100

150

200

250

300

350

400

Liquid Cooled Output

Advertising