9. remote 14 socket information – Miller Electric ProHeat 35 User Manual

Page 22

Advertising
background image

OM-222 166 Page 16

803 993-C

4-8. Remote 14 Receptacle RC14 Information and Connections

1

Plug

2

Threaded Collar

3

Keyway

4

Remote 14 Receptacle RC14

(See Section 4-9)

To connect to receptacle, align key-

way, insert plug and tighten

threaded collar.

A

J

B

K

I

C L N

H

D M

G

E

F

3

4

2

1

1

2

4-9. Remote 14 Socket Information

Socket

Socket Information

A

Remote Contactor

+24 volts dc.

B

Remote Contactor

Contact closure to A completes 24 volts dc contactor control circuit.

C

Command reference; +10 volts dc.

D

Remote Output Control

Control circuit common.

E

Remote Output Control

Input command signal (potentiometer wiper or 0 to +10 volts dc).

G

Not used.

F, J

Power Source Limit

Absence of internal contact closure between F and J signals power source error to remote

control device.

H

Not used.

I

Actual frequency output signal (1 volt/10 kHz).

L

Remote Metering

Average power output signal (1 volt/10 kW).

M

Remote Metering

Voltage output signal RMS (1 volt/100 volts).

N

Total current output signal RMS (1 volt/100 amperes).
Ch

i

K

Chassis common.

Advertising