4-2. manual control – Miller Electric ProHeat 35 User Manual

Page 38

Advertising
background image

OM-222 166 Page 32

Typical 5-Segment Custom Program

Mode.......: Custom Program
Segment....: 1
Type.......:>Step
Temperature: 600

Custom Program Screen

Temperature increases to 600 degrees at full-programmed power.

Mode.......: Custom Program
Segment....: 2
Type.......: Ramp
Temperature:>1250 Ramp Rate: 600

_/Hr

Custom Program Screen

Controlled heating to 1250 degrees F at a ramp of 600 degrees per hour.

Mode.......: Custom Program
Segment....: 3
Type.......: Soak
Soak Time..:>01:00:00

Custom Program Screen

Soak at 1250 degrees F for a period of 1:00.

Mode.......: Custom Program
Segment....: 4
Type.......:>Ramp
Temperature: 600 Ramp Rate: 600

_/Hr

Custom Program Screen

Controlled cooling to 600 degrees F at a rate of 600 degrees per hour.

Mode.......: Custom Program
Segment....: 5
Type.......: End
Control TC.: 1

Custom Program Screen

End segment ends the heat treat cycle. Controller is programmed to control the process using four thermocouples.

6-4-2.

Manual Control

Manual control allows programming of a specific power level for a specific period of time. When this process is selected, the following screen appears

on the display: