4-10. Temperature Recorder Receptacle RC9 Information And Connections
1
Plug
2
Threaded Collar
3
Temperature Recorder
Receptacle RC9 (See Section
To connect to receptacle, insert
plug and tighten threaded collar.
3
2
1
1
2
4-11. Temperature Recorder Socket Information
Socket No.
Socket Information
1
Thermocouple No. 1 (TC1), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]
2
Thermocouple No. 2 (TC2), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]
3
Thermocouple No. 3 (TC3), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]
4
Thermocouple No. 4 (TC4), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]
5
Signal Common
6
Thermocouple No. 5 (TC5), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]
7
Thermocouple No. 6 (TC6), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]
8
Unused
9
Unused
10
Chassis Ground
11
Unused
12
Unused
13
Unused
14
Unused