11. temperature recorder socket information – Miller Electric ProHeat 35 User Manual

Page 23

Advertising
background image

OM-222 166 Page 17

803 993-C

4-10. Temperature Recorder Receptacle RC9 Information And Connections

1

Plug

2

Threaded Collar

3

Temperature Recorder

Receptacle RC9 (See Section

4-11)

To connect to receptacle, insert

plug and tighten threaded collar.

3

2

1

1

2

4-11. Temperature Recorder Socket Information

Socket No.

Socket Information

1

Thermocouple No. 1 (TC1), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]

2

Thermocouple No. 2 (TC2), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]

3

Thermocouple No. 3 (TC3), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]

4

Thermocouple No. 4 (TC4), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]

5

Signal Common

6

Thermocouple No. 5 (TC5), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]

7

Thermocouple No. 6 (TC6), 0-10 volt dc signal [0V = −50° F (−46° C), 10V = 1500° F (816° C)]

8

Unused

9

Unused

10

Chassis Ground

11

Unused

12

Unused

13

Unused

14

Unused

Advertising