OM-222 166 Page 29

Mode.......: Custom Program
Segment....: 1
Type.......: End
Control TC.: 1

Custom Program Screen

The default position of the cursor is next to Segment. Press the Increase

or Decrease

button to increase or decrease the

segment number, unless the segment type is End. In this case, the segment number will advance to segment 1.

Use the Cursor

button to move the cursor to the desired selection (Type or Control TC), and press the Increase

or Decrease

button to change the value to the desired setting. When the cursor is moved to the Type selection, pressing the Increase

or

Decrease

button changes the segment type to Step, Ramp, Soak, or End. The functions of each segment type are as follows:

S

Step increases the temperature in the part at full-programmed power. A maximum temperature of 1450° F

(788° C) can be programmed.

S

Ramp increases or decreases the temperature in the part at a controlled rate in degrees per hour. A

maximum temperature of 1450° F (788° C) and a maximum rate of 9999° F/hr (5555° C/hr) can be

programmed.

S

Soak will hold the temperature for a programmed time. A maximum hold (soak) time of 99:59

(hours:minutes) can be programmed.

S

End is programmed to indicate the completion of the cycle and termination of output power.

Step Function

When type is set to Step, the following screen appears on the display:

Mode.......: Custom Program
Segment....: 1
Type.......:>Step
Temperature: 600

Custom Program Screen

Use the Cursor

button to move the cursor to the Temperature position and the initial temperature can be adjusted using the Increase

or Decrease

button.

Pressing the Cursor

button again automatically advances the program to the next segment number.

Ramp Function

When type is set to Ramp, the following screen appears on the display:

Advertising