OM-222 166 Page 30
Mode.......: Custom Program
Segment....: 1
Type.......: Ramp
Temperature: 600 Ramp Rate: 600
_/Hr
Custom Program Screen
Use the Cursor
button to move the cursor to the Temperature or Ramp Rate position and use the Increase
or Decrease
button to set the desired value.
When the cursor is in the Ramp Rate position, pressing the Cursor
button again automatically advances the program to the next segment
number.