Miller Electric ProHeat 35 User Manual

Page 37

Advertising
background image

OM-222 166 Page 31

Soak Function

When type is set to Soak, the following screen appears on the display:

Mode.......: Custom Program
Segment....: 1
Type.......:>Soak
Soak Time..: 00:01:00

Custom Program Screen

Use the Cursor

button to move the cursor to the Soak Time position and use the Increase

or Decrease

button to set

the desired value.

When the cursor is in the Soak Time position, pressing the Cursor

button again automatically advances the program to the next segment

number.

End Function

When type is set to End, the following screen appears on the display:

Mode.......: Custom Program
Segment....:> 2
Type.......: End
Control TC.: 1

Custom Program Screen

The only changeable parameter in the End segment is selecting the number of thermocouples. Use the Cursor

button to move the cursor

to the Control TC position. Press the Increase

or Decrease

button to select the number of control thermocouples to be used for

the program. Selections are as follows: 1, 1,2, 1,2,3, or 1,2,3,4. TC1 MUST always be a control thermocouple. TC2 thru TC4 can be used for

controlling or monitoring. When a thermocouple is selected as control, the LED adjacent to the seven-segment display illuminates.

A custom program can contain up to 10 segments. To view Program parameters, position the cursor at segment and use the Increase

or

Decrease

button to advance through the segment numbers until the End segment. When a segment number is changed, appropriate

segment parameter information appears on the display.

Advertising