Electrical specifications - power, continued, Motor output specifications table, Parameter – Schneider Electric Lexium 17S Series User Manual

Page 102: Output current (rms), Continuous, Mhds1004n00, Mhds1008n00, Mhds1017n00, Mhds1028n00, 10 a

Advertising
background image

90

Electrical Specifications - Power, continued

Motor Output
Specifications
Table

The following table provides 17S motor output specifications.

Note: Motors must be compatible with following table:

Continued on next page

Parameter

Type

Model Number

Current

Output current (RMS)

Continuous

MHDS1004N00*

1.5 A

MHDS1008N00

3 A

MHDS1017N00

6 A

MHDS1028N00

10 A

MHDS1056N00

20 A

Intermittent**

MHDS1004N00

3 A

MHDS1008N00

6 A

MHDS1017N00

12 A

MHDS1028N00

20 A

MHDS1056N00

40 A

Switching frequency

8 kHz ± 0.1%

Cable length***

75 m (maximum)

Maximum cable capacitance (motor
phase to ground or shield)

150 pF/m

* For single phase main connection, the output current is limited to the output

current specifed above or 4 amps, whichever is lower.

** Duration depends on settings in Unilink.
*** Cable lengths exceeding 25 m require the use of motor choke AM0FIL001V056

Motor Inductance:

Model

Min (mH)

Max (mH)

MHDS1004N00

16

400

MHDS1008N00

8

200

MHDS1017N00

4

100

MHDS1028N00

3.5

60

MHDS1056N00

1.5

30

Advertising