Wire specifications (recommended), Wire specifications, Item – Schneider Electric Lexium 17S Series User Manual

Page 111: Drive model no, Wire size, Notes, Ac mains, Mhds1004n00, Mhds1008n00, Mhds1017n00

Advertising
background image

99

Wire Specifications (Recommended)

Wire
Specifications

The following table lists the recommended wire specifications. Use only copper wire
with insulation rated at 75

°

C or greater, unless otherwise specified.

Item

Drive Model No.

Wire Size

Notes

AC mains

MHDS1004N00
MHDS1008N00
MHDS1017N00
MHDS1028N00

1.5 mm

2

(14 AWG)

MHDS1056N00

4.0 mm

2

(12 AWG)

Protective earth

All

4.0 mm

2

(12 AWG)

DC Link

MHDS1004N00
MHDS1008N00
MHDS1017N00
MHDS1028N00

1.5 mm

2

(14 AWG)

Shielded for lengths
greater than 20cm

MHDS1056N00

4.0 mm

2

(12 AWG)

Shielded for lengths
greater than 20cm

Analog signals

All

0.25 mm

2

(22 AWG)

minimum

Twisted pairs,
shielded

Digital I/O and Fault
Relay

All

0.5 mm

2

(20 AWG)

minimum

Brake

All

1.0 mm

2

(18 AWG)

minimum

Shielded

Bias power

All

2.5 mm

2

(14 AWG)

maximum

Optional external
Regen resistor

All

1.5 mm

2

(14 AWG)

High temperature

insulation (155

°

C or

greater)

Advertising