Warning messages, Warning identification and description, Warning code – Schneider Electric Lexium 17S Series User Manual

Page 88: Designation, Explanation, I·t warning, Regen power, Following fault, Response monitoring, Response monitoring (fieldbus)is active

Advertising
background image

76

Warning Messages

Warning
Identification
and Description

A warning is generated when a non-fatal fault occurs. Non-fatal faults allow the
drive to remain enabled and the fault relay contact to remain closed. Either of the
programmable digital outputs can be programmed to indicate that a warning
condition has been detected. The cause of the warning is presented as an
alphanumeric code on the drive’s front panel LED display; these warning codes are
identified and described in the following table.

Warning
Code

Designation

Explanation

n01

I²t warning

Current threshold set by “I²t Message” parameter
was exceeded.

n02

Regen power

Power threshold set by “Max Regen Power”
parameter was exceeded.

n03

Following Fault

Following error threshold set by “Following Error”
parameter was exceeded.

n04

Response monitoring

Response monitoring (fieldbus)is active.

n05

Mains phase

Mains phase missing. Can be disabled for single
phase operation with the “Mains Phase Missing”
parameter.

n06

Sw limit-switch 1

Passed software limit-switch 1.

n07

Sw limit-switch 2

Passed software limit-switch 2.

n08

Motion task error

A faulty motion task was started.

n09

No “Home” reference point

Motion task started with no “Home” reference
point set.

n10

Positive Limit

Positive limit-switch activated.

n11

Negative Limit

Negative limit-switch activated.

n12

Default values

Only HIPERFACE®: motor default values loaded.

n13

SERCOS interface

SERCOS interface not functioning correctly.

n14

HIPERFACE®-reference
mode

Attempt to reset while HIPERFACE®-reference
mode was active.

n15

Table error

Velocity current table INXMODE 35 error

n16 ... n31 Reserved

reserved

n32

Firmware beta version

The firmware is not a released beta version

A

Reset

RESET is active at DIGITAL IN x

Advertising