Electrical Specifications - Regen Resistor

Regen Circuit
Specifications

The following table provides technical data on the Regen circuit.

Parameter

Rated data

Units

Model Number

(prefix with MHDS10)

04N00
08N00

17N00
28N00
56N00

Supply Voltage

3

phase

,

230 V

Upper switch-on level of Regen circuit

V

400 - 430

Switch-off level of Regen circuit

V

380 - 410

Continuous power of Regen circuit (RBint)

W

80

200

Continuous power of Regen circuit (RBext)
maximum.

kW

0.25

0.75

Pulse power, internal (RBint max. 1s)

kW

2.5

5

Pulse power, external (RBext max. 1s)

kW

5

3 phase

,

400 V

Upper switch-on level of Regen circuit

V

720 - 750

Switch-off level of Regen circuit

V

680 - 710

Continuous power of Regen circuit (RBint)

W

80

200

Continuous power of Regen circuit (RBext)
max.

kW

0.4

1.2

Pulse power, internal (RBint max. 1s)

kW

8

16

Pulse power, external (RBext max. 1s)

kW

16

3 phase

,

480 V

Upper switch-on level of Regen circuit

V

840 - 870

Switch-off level of Regen circuit

V

800 - 830

Continuous power of Regen circuit (RBint)

W

80

200

Continuous power of Regen circuit (RBext)
maximum.

kW

0.5

1.5

Pulse power, internal (RBint maximum 1s)

kW

10.5

21

Pulse power, external (RBext maximum 1s)

kW

21

External Regen resistor

33

Internal Regen resistor

66

33