Troubleshooting, continued, Problem, Possible causes – Schneider Electric Lexium 17S Series User Manual

Page 94: Corrective actions, Motor oscillates, Gain too high (speed controller), Shielding in feedback cable has a break, Reduce kp (speed controller), Replace feedback cable, Poor drive performance (drive too soft)

Advertising
background image

82

Troubleshooting, continued

Problems,
Possible Causes
and Corrective
Actions
,
continued

Problem

Possible Causes

Corrective Actions

Motor oscillates

- Gain too high (speed controller).

- Shielding in feedback cable has
a break.

- Reduce Kp (speed controller).

- Replace feedback cable.

Poor drive
performance
(drive too soft)

- Kp (speed controller) too low.

- Tn (speed controller) too high.

- PID-T2 too high.

- T-Tacho too high.

- Increase Kp (speed controller).

- Use motor default value for Tn
(speed controller).

- Reduce PID-T2.

- Reduce T-Tacho.

Motor runs
roughly

- Kp (speed controller) too high.

- Tn (speed controller) too low.

- PID-T2 too low.

- T-Tacho too low.

- Reduce Kp (speed controller).

- Use motor default value for Tn
(speed controller).

- Increase PID-T2.

- Increase T-Tacho.