Error messages, continued, Error identification and description, continued, Error code – Schneider Electric Lexium 17S Series User Manual
Page 90: Error (fault), Possible cause/corrective action, Motor overtemperature, Irms or ipeak set too high, Defective motor, Reduce motion profile duty cycle, Improve ventilation of the motor
![background image](/manuals/143587/90/background.png)
78
Error Messages, continued
Error
Identification
and Description,
continued
Continued on next page
Error
Code
Error (Fault)
Possible Cause/Corrective Action
F06
Motor overtemperature.
- I
rms
or I
peak
set too high.
- Defective motor
- If motor is not hot, check feedback cables and
connectors.
- Reduce motion profile duty cycle
- Improve ventilation of the motor
F07
Internal 24 Vdc fault.
Return drive to manufacturer
F08
Motor speed limit
exceeded.
- Feedback parameters not set correctly.
- Incorrect feedback wiring.
- Motor phases reversed.
- Check Parameter “Overspeed” for correct setting.
F09
EEPROM checksum error. Return drive to manufacturer.
F10
Flash-EPROM checksum
error.
Return drive to manufacturer.
F11
Motor brake fault.
- Brake parameter set to “WITH” when brake does not
exist.
- Defective brake.
- Check motor power cable and connections.
F12
Motor phase missing.
- Defective motor.
- Check motor power cable and connections
F13
Drive internal temperature
exceeded.
- Improve ventilation.
- Reduce motion profile duty cycle.